1.
Chinese Journal of Zoonoses ; (12): 441-448, 2017.
Article in Chinese | WPRIM | ID: wpr-620063

ABSTRACT

We developed a universal probe based microRNA detection assay and applied it to detect microRNA-146a in human brucellosis,testing the possibility of using it as diagnosis signature.By using orthogonal design,the annealing temperature,probe concentration and commercial kits were optimized and the assay was developed.Total RNAs were isolated from plasma of human brucellosis and healthy control,and microRNA-146a was detected and compared.Results reveal that the optimized universal probe assay was established,which was more specific than the SYBR GreenI assay,and had a wider range of amplification.Compared with healthy control,the application of universal probe assay for the detection of serum microRNA146a in patients with brucellosis was significantly inhibited (P<0.01).Implying the potential of microRNA-146a as biomarker in diagnosis of brucellosis.It is suggested that universal probe based assay is a universal,specific and sensitive method for microRNA detection.MicroRNA-146a represents a potential biomarker for human brucellosis diagnosis.

2.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 683-685, 2015.
Article in Chinese | WPRIM | ID: wpr-478476

ABSTRACT

Objective To investigate why benign, paroxysmal positional vertigo (BPPV) recurs.Methods Three hundred persons diagnosed with BPPV who had been treated at Tongji Hospital of Huazhong University of Science and Technology between April 2012 and April 2014 were given a telephone follow-up at least one year after their manual repositioning treatment.The respondents were divided into a healthy group and a recurrence group according to whether they said their vertigo had recurred.The age and gender distributions of the two groups were compared, along with their underlying diseases and living-related factors.Causes of the recurrence were then hypothesized.Results Single factor analysis and binary logistic regression analysis showed that overwork, an age over 45, travelling frequently, long use of computers, sleep disorders, oral intake of calcium tablets, posterior circulation ischemia and hyperlipidemia were all closely related to the BPPV recurrence.Age over 45 showed the strongest correlation.Conclusion Aging is the greatest risk factor for the recurrence of BPPV.Posterior circulation ischemia, hyperlipidemia, overwork, sleep disorders, long use of computers and being on business frequently are also predictors of relapse.

3.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 196-198, 2013.
Article in Chinese | WPRIM | ID: wpr-434674

ABSTRACT

Objective To investigate the difference of clinical efficiency and safety in obsessive-compulsive disorders (OCD) treatment with escitalopram or paroxetine.Methods A total of 156 OCD patients were randomly divided into escitalopram group (ESC group) and paroxetine group (PAR group).Yale-Brown Obsessive Compulsive Scale (Y-BOCS),Hamilton Depression Scale (HAMD) and Treatment Emergent Symptom Scale (TESS)were used to evaluate the clinical efficiency and safety before and after1,2,4,6,8 weeks treatment.Results The cure rate(21.79% vs 17.95%) and effective rate(70.51% vs 71.79%) had no statistically difference between ESC group and PAR group,and incidence of side effect had no significant difference between two groups(x2 =1.99,P>0.05).Compared with the group before treatment,HAMD scores were significantly decreased from the first weekend in ESC group,but in PAR group HAMD scores did not decrease until the second weekend,and the differences were also significant(P<0.05).Conclusion Escitalopram is a safety,effective and well-tolerated drug in the treatment of obsessive-compulsive disorder.

4.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 205-207, 2013.
Article in Chinese | WPRIM | ID: wpr-434663

ABSTRACT

Objective To examine the effect of family environment and family function on suicide behavior in schizophrenic patients.Methods 53 schizophrenic patients with suicidal behavior in the last month were selected for the schizophrenic suicide group.53 schizophrenic patients and 53 normal controls matched with the schizophrenic suicide group were selected for the schizophrenic no suicide group and normal control group.All of them completed family environment scale and family assessment device.Results The cohesion factor,the expressiveness factor,the active-recreational orientation factor and the control factor of family environment scale in the schizophrenic suicide group were significant lower than those in the schizophrenic without suicide group(separately 5.70 ± 1.29 vs 6.62± 1.23,4.77 ± 1.49 vs 5.96 ± 1.11,3.94 ± 1.63 vs 5.68 ± 1.98,2.68 ± 1.68 vs 4.40 ± 1.81,P< 0.05),but the conflict factor in the schizophrenic suicide group was higher than in the schizophrenic without suicide group(3.55 ± 1.60 vs 2.81 ± 1.52,P < 0.05).The affective responsiveness factor,the affective involvement factor and the behavior control factor of family assessment device in the schizophrenic suicide group were significant lower than those in the schizophrenic without suicide group(separately 16.05 ± 2.57 vs 14.53 ± 3.38,19.13 ± 4.09 vs 16.58 ± 2.82,23.35 ± 3.52 vs 21.60 ± 3.25,P < 0.05).Multiple liner regression analyses showed that the expressiveness factor,the active-recreational orientation factor,the control factor,the affective involvement factor and the behavior control factor were important factors for schizophrenic suicide(F=21.583,P=0.000,adjusted R 2 =0.519).Conclusion Attempted suicide patients with schizophrenia have some deficiencies at family function and family environment.

5.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 2425-2426, 2012.
Article in Chinese | WPRIM | ID: wpr-427870

ABSTRACT

ObjectiveTo explore the clinical value of 256-slice CT and coronary angiography in the diagnosis of coronary artery disease.Methods46 patients with coronary heart disease,who underwent coronary angiography and 256-slice spiral CT were selected.Compare two methods for the detection of coronary artery disease.Results( 1 ) All 256-slice CT and coronary angiography achieved a satisfactory image,in the diagnosis of coronary artery stenosis and occlusion,the two methods had no statistically significant difference ( P > 0.05 ).(2) according to standard coronary angiography,256-slice spiral CT for the diagnosis of coronary artery stenosis sensitivity was 93.0% (132/142),specificity was 91.6% (142/155),positive predictive rate was 91.0% (132/145),negative predictive rate was 93.4% (142/152).Conclusion256-slice spiral CT has a high time resolution,spatial resolution,the display of the coronary artery disease has high sensitivity,specificity,positive predictive value and negative predictive value.

6.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1769-1770, 2012.
Article in Chinese | WPRIM | ID: wpr-427825

ABSTRACT

Objective To explore the clinical value of CT in diagnosis of pulmonary Wegener's granulomatosis.Methods The clinical data of 11 cases with Wegener's granulomatosis of the lungs were selected.All patients underwent CT scan or enhanced MRI scans and misdiagnosis of CT images were analyzed.Results This group of patients with bilateral lung injury in 9 cases,unilateral lung injury in 2 cases.Main imaging features include:multiple nodules in 8 cases,irregular flakes consolidation shadow in 4 cases,wedge-shaped lesion in 3 cases,empty in 6 cases.Among 11 patients,8 patients were misdiagnosed,misdiagnosis rate was 72.72% (8/11),of which 2 cases were misdiagnosed as primary lung cancer,3 cases were misdiagnosed as metastatic lung cancer,3 cases were misdiagnosed as tuberculosis.Conclusion The CT manifestations had a very important role in guiding the diagnosis of pulmonary Wegener's granulomatosis.

7.
Journal of Pharmaceutical Analysis ; (6): 85-86, 2000.
Article in Chinese | WPRIM | ID: wpr-621856

ABSTRACT

Objective To establish a speed and effective method to detect rotavirus. Methods Using ELISA and one step RT-PCR to detect 196 clinic samples from Xi'an area. Results Compared with ELISA method, one step RT PCR was more sensitive and specific (P <0.05). Conclusion One step RT-PCR is a simple, speed, sensitive and spe cific method for clinic and epidemic studies of rotavirus.